International Water Ski Federation 2003 Edition Homologation Dossier IMPORTANT NOTICE: It is not the intent of this form to add hours of extra work to the homologator's job, but rather to provide a quick checklist that gives visibility of the technical effort to the general skiing public. START OF HOMOLOGATION FORM code of competition: 06S028R name of competition: H2Osmosis Sports Swerve Date: Aug. 27 & 28, 2005 Venue:Trophy Lakes @ Lake #1 Organizing Country: USA Type of competition ( International ) Were cash prizes or merchandise awarded (Yes/No) ( No ) Homologator's and Chief Judge recommendation to Tournament Council (Fill in R-Record, L-Standing List, N-Not list capable) Event Round 1 Round 2 Round 3 Round 4 Slalom (R,E,L) (R,E,L) (R,E,L) ( ) Tricks ( ) ( ) ( ) ( ) Jump ( ) ( ) ( ) ( ) OBLIGATORY COMPOSITION OF DOSSIER: 1 copy of this document including the homologation notice HOMOLOGATOR'S CHECKLIST If checked and all according to rules put OK in brackets. If checked and any variation to the rules put an X in the brackets and explain in "Remarks" section on last page. Not applicable is NA. 1. Boats and equipment (W 10.01) (OK) 2. Speed Control (W 10.07) (OK) Maunfacturer: Perfect Pass Software Version: 6.5N slalom (OK) tricks ( ) jump ( ) 3. Arrangement for checking skis (W 10.03) (OK) 4. Measure lines and handles (W 10.04) (OK) slalom (OK) jump ( ) handles (OK) 5. Arrangement for checking of skier supplied handles (W 10.06) (OK) 6. Timing devices (W 11.03) (OK) 7. Homologation notice posted before start (OK) 8. Automatic timing-jump ( ) Optional Timing Method ( ) 9. Jump distance indication (W 13.11) ( ) 10.Video Jump Distance measurement (W 13.11)( ) Backup - video tape or standard meters ( ) 11.Automatic timing-slalom Dual Segment (NA) All Buoys (OK) 12.Position and height of slalom towers (OK) (W 14.05 and W diagram 6) 12a. 2 Towers x 2 Judges ( ) 2 Central Tower Judges (OK) Boat Video ( ) 13.Slalom buoys (W 14.06) (OK) 14.VHS video slalom endcourse (W 14.17) (OK) 15.Trick course checked (W diagram 3) ( ) 16.Position and height of trick towers ( ) (W 15.11) 16a. 5 Judges ( ) 1 x 3 Judges with video (OK) 2x 3 Judges with video ( ) 17.Semi-automatic timing-20sec (W 15.12) ( ) automatic median start ( ) 17a. Video Tricks Timing ( ) with Additional judge ( ) Chief Judge ( ) 18.VHS video tricks (W15.15) ( ) 19.7,000/10,000 points review judge ( ) (W 15.15) 19a.Video Tricks Timing system manufacturer ( ) SLALOM COURSE TYPE : Cross wire anckors JUMP COURSE JUMP MEASUREMENT SETUP VIDEO JUMP 40m Test buoy Survey x (XXX.XX) y (XXX.XX) Video system x (XXX.XX) y (XXX.XX) 60m Test buoy Survey x (XXX.XX) y (XXX.XX) Video system x (XXX.XX) y (XXX.XX) JUMP RAMP Width at top (W 13.02a) X.XX m Width at bottom X.XX m Top edge to 6.4m line left side (W 13.02b,h) X.XX m Top edge to 6.4m line right side (W 13.02b.h) X.XX m Top edge to 6.7m line left side (W 13.02b,h) X.XX m Top edge to 6.7m line right side (W 13.02b.h) X.XX m Length underwater from 6.7m line (W 13.02c) X.XX m Maximum Deviation from plane Diagonal string measurement (W 13.02f) X.X cm Center string measurement (W 13.02f) X.X cm (OK/X) Apron under water (W 13.02g) ( ) Apron full length (W 13.02g) ( ) Sighting line (W 13.02i) ( ) Secure anchoring (W 13.02i) ( ) Apron Angle (W 13.02k) jump height X.XX m (a) length of edge of apron from top corner to water X.XX m (b) ratio of b/a (X.XXX) ( ) minimum 0.883 maximum 0.643 RAMP SETTING Right Side Left Side Setting Height Length Ratio Height Length Ratio 1.50 XXX.X XXX.X XXX.X XXX.X XXX.X XXX.X 1.65 XXX.X XXX.X XXX.X XXX.X XXX.X XXX.X 1.80 XXX.X XXX.X XXX.X XXX.X XXX.X XXX.X NON-VIDEO JUMP Note: The following section is only to be completed if the jumps were measured by protractors rather than video. Automatic meter system used (Yes/No) ( ) Protractor reading units (Degrees/Grades) ( ) METER SETUP Distance (T1 - T2/A - B) (XXX.XX meters) Distance (T2 - T3/B - C) (XXX.XX meters) if not a straight line Distance (T1 - T3/A - C) (XXX.XX meters) Inter-meter angles (if not a straight line) T1/A T2/B T3/C Meter T1/A XXXXX 180.0 180.0 Meter T2/B 0.0 XXXXX 180.0 Meter T3/C 0.0 0.0 XXXXX (note shown numbers are examples - fill in with actual numbers) SET UP SIGHTINGS Angle Ramp 15ET T1/A upper XXX.X XXX.X T1/A lower XXX.X XXX.X T2/B upper XXX.X XXX.X T2/B lower XXX.X XXX.X T3/C upper XXX.X XXX.X T3/C lower XXX.X XXX.X Using average of upper and lower readings (max difference 0.1 degrees) list the error triangles with an inscribed circle diameter (max 0.15) inscribed circle diameter at ramp X.XX meters inscribed circle diameter at 15ET X.XX meters Jump system survey results (X-Y coordinates) X Y Ramp XXX.XX XXX.XX Table 1/A XXX.XX XXX.XX Table 2/B XXX.XX XXX.XX Table 3/C XXX.XX XXX.XX Buoy 15ET XXX.XX XXX.XX Attach the computer printout file at the end after the Homologation Notice Computer program checked against (OK/X) "Computer Benchmark for Computed Distances" ( ) METER STATIONS Stability and horizontal level ( ) Protractors on same vertical line ( ) Protractor graduations (max 0.2 degrees) ( ) Radius of protractors (min 0.25 m) ( ) Accuracy of sighting arms ( ) END OF HOMOLOGATION FORM It is important to leave the above section in the exact format as it will be processed automatically. The following section is where free form comments are added and attachments are made. HOMOLOGATOR'S REMARKS Give details of any variations of IWSF rules. List any alterations to the course, etc. duringthe competition. List any malfunction of equipment. Give any further information which might affect the Tournament Council's assement of the homologation. No variations of IWSF rules. Used video gates with cameras placed @ 44 +/- degree location, transmittted video via wire to the near and far side center judge towers which were located near the center of the lake. East end of lake camera for center line video transmitted via wired to near side center judge tower and recorded on VHS recorder and TIVO hard drive DVR. Course surveyed on 8-24-05 by Slade Cole, TC from the 3 points A, B & C set by Ed Brazil, TC and Jerry Jackson, TC several years ago on the Far side (South) of the lake.The course was found to be acceptable. Weather was overcast on Saturday, and Sunday with a few thundershowers in the afternoon on Saturday. Richard Lacey, TC Adjusted ropes prior to the tournment. Jerry Jackson rewired far side video feed and provided the computed equipment and training for live and post checking of the slalom course boat path. Records pending that occured during this competition: Open Men - Chris Parrish, 1.5 buoys @ 43 off. AWSA Women 4 - Phillipa Shedd, 2.25 buoys @ 38 0ff Japan Men 2 - Shinobu Okasako, 1 buoy @ 39 1/2 off Homologator: Slade Cole 1600 Telfair Road Savannah, GA 31415-9519 Email: slade.cole@comcast.net Chief Judge: (name and address) Ray Crenshaw Toccoa, GA 30577-9122 This homologation record has been emailed to bcorson@comcast.net for EAME: email also to abottinelli@bluewin.ch ----------------------------------------------------------------------------- To be posted before the tournament starts HOMOLOGATION NOTICE Tournament Name: H2Osmosis sports Swerve Date: Aug 27 and 28, 2005 We recommend to the IWSF Tournament Council the following class of homologation: Event Round 1 Round 2 Round 3 Round 4 Slalom (R,E,L) (R,E,L) (R,E,L) ( ) Tricks ( ) ( ) ( ) ( ) Jump ( ) ( ) ( ) ( ) Speed Control Manufacturer: Perfect Pass Software Version: 6.5N Mode for tricks (if applicable):________________________ Date 8-27-2005 ________ _______ Time 7:00 am ________ _______ Chief Judge Homologator Ray Crenshaw ____________ Slade Cole ________________ Note: These recomendations may change during the competition. Remarks: End of Document